Smartctl: Unterschied zwischen den Versionen

Aus Foxwiki
Robertquies (Diskussion | Beiträge)
Robertquies (Diskussion | Beiträge)
Zeile 135: Zeile 135:
                                         Selective Self-test supported.
                                         Selective Self-test supported.
  SMART capabilities:            (0x0003) Saves SMART data before entering
  SMART capabilities:            (0x0003) Saves SMART data before entering
                                        power-saving mode.
                                        power-saving mode.
                                        Supports SMART auto save timer.
                                        Supports SMART auto save timer.
  Error logging capability:        (0x01) Error logging supported.
  Error logging capability:        (0x01) Error logging supported.
                                        General Purpose Logging supported.
                                        General Purpose Logging supported.
  Short self-test routine  
  Short self-test routine  
  recommended polling time:        (  1) minutes.
  recommended polling time:        (  1) minutes.
Zeile 144: Zeile 144:
  recommended polling time:        ( 241) minutes.
  recommended polling time:        ( 241) minutes.
  SCT capabilities:              (0x003d) SCT Status supported.
  SCT capabilities:              (0x003d) SCT Status supported.
                                        SCT Error Recovery Control supported.
                                        SCT Error Recovery Control supported.
                                        SCT Feature Control supported.
                                        SCT Feature Control supported.
                                        SCT Data Table supported.
                                        SCT Data Table supported.


=weiterführende Artikel=
=weiterführende Artikel=

Version vom 28. Juli 2020, 12:00 Uhr

smartctl

  • Kommandozeilentool zur Steuerung der SMART-Funktionen (Self-Monitoring, Analysis and Reporting Technology) von Datenträgern, wie Festplatten, SSDs und Bandlaufwerken.
  • Ist Bestandteil der Smartmontools.
  • Für zahlreiche Betriebssysteme verfügbar:
    • Linux, FreeBSD, NetBSD, OpenBSD, Solaris, Windows
    • Hier geht es um Linux.

Funktion

  • Überwachung der Zuverlässigkeit von Datenträgern.
  • Durchführung von Laufwerkstests.

Installation

#apt install smartmontools

Syntax

smartctl [options] device
  • Pfad zum Befehl
    • /usr/sbin/smartctl

Optionen

Option Erklärung
-i Ist S.M.A.R.T. verfügbar?
-h Übersicht (aller) Optionen.
-s on S.M.A.R.T. wird aktiviert.
-a Zusammenfassende Ausgabe aller Festplatteninformationen und Testergebnisse.
-A Werte aller Attribute.
-H Abfrage Gesundheitszustand.
-c Anzeige Testmöglichkeiten / dafür benötigte Zeit / Anzeige momentaner Testfortschritt.
-S on Autom. Speichern d. Einstellungen.
-t long Startet langen selftest (Oberflächenanalyse).
-t short Startet kurzen selftest. Dauert mind. 1 Minute. Endzeit angegeben.
-t offline Startet sofort Offline Tests (Anzeige mit -l error oder -a)
-l selftest kleines L - Zeigt Log des letzten Selbsttests
-X Test abbrechen
-l error kleines L - Ausgabe Fehlermeldungen


Beispiele

Kurztest des Datenträgers sdb

# smartctl -t short /dev/sdb
smartctl 6.6 2017-11-05 r4594 [x86_64-linux-4.19.0-9-amd64] (local build)
Copyright (C) 2002-17, Bruce Allen, Christian Franke, www.smartmontools.org

=== START OF OFFLINE IMMEDIATE AND SELF-TEST SECTION ===
Sending command: "Execute SMART Short self-test routine immediately in off-line mode".
Drive command "Execute SMART Short self-test routine immediately in off-line mode" successful.
Testing has begun.
Please wait 1 minutes for test to complete.
Test will complete after Tue Jul 28 11:58:53 2020

Use smartctl -X to abort test.

Ergebnisanzeige vom letzten Kurztest des Datenträgers sdb

# smartctl -l selftest /dev/sdb
smartctl 6.6 2017-11-05 r4594 [x86_64-linux-4.19.0-9-amd64] (local build)
Copyright (C) 2002-17, Bruce Allen, Christian Franke, www.smartmontools.org

=== START OF READ SMART DATA SECTION ===
SMART Self-test log structure revision number 1
Num  Test_Description    Status                  Remaining  LifeTime(hours)  LBA_of_first_error
# 1  Short offline       Completed without error       00%     11116         -
# 2  Short offline       Completed without error       00%     11115         -
# 3  Extended offline    Completed without error       00%     11027         -
# 4  Short offline       Completed without error       00%     11022         -
# 5  Extended offline    Completed without error       00%      9272         -
# 6  Short offline       Completed without error       00%      4272         -
# 7  Short offline       Completed without error       00%       238         -
# smartctl -c /dev/sdd
smartctl 6.6 2017-11-05 r4594 [x86_64-linux-4.19.0-9-amd64] (local build)
Copyright (C) 2002-17, Bruce Allen, Christian Franke, www.smartmontools.org

=== START OF READ SMART DATA SECTION ===
General SMART Values:
Offline data collection status:  (0x80) Offline data collection activity
                                        was never started.
                                        Auto Offline Data Collection: Enabled.
Self-test execution status:      (   0) The previous self-test routine completed
                                        without error or no self-test has ever 
                                        been run.
Total time to complete Offline 
data collection:                (14439) seconds.
Offline data collection
capabilities:                    (0x5b) SMART execute Offline immediate.
                                        Auto Offline data collection on/off support.
                                        Suspend Offline collection upon new
                                        command.
                                        Offline surface scan supported.
                                        Self-test supported.
                                        No Conveyance Self-test supported.
                                        Selective Self-test supported.
SMART capabilities:            (0x0003) Saves SMART data before entering
                                        power-saving mode.
                                        Supports SMART auto save timer.
Error logging capability:        (0x01) Error logging supported.
                                        General Purpose Logging supported.
Short self-test routine 
recommended polling time:        (   1) minutes.
Extended self-test routine
recommended polling time:        ( 241) minutes.
SCT capabilities:              (0x003d) SCT Status supported.
                                        SCT Error Recovery Control supported.
                                        SCT Feature Control supported.
                                        SCT Data Table supported.